Simple Simon® PT [ZAF-101] – near patient PT INR according to Owren method performed at ambient room temperature
Simple Simon® PT measures prothrombin complex (PK) in INR.
Simple Simon® PT (SSPT) is intended for in-patient analysis of prothrombin time expressed in INR (PT-INR). The analyte is also called prothrombin complex activity (PK) or tissue factor-induced coagulation time. SSPT is intended for smaller laboratories at hospitals, health centers, medical stations and doctors’ offices. The product can contain ZAF-103 MixxoCap® and has IT support when the product is used with ZAF-552 Zafena POC-Workstation and ZAF-550 Connector.
The Simple Simon concept ® is for patient-centered, wet chemical laboratory diagnostics. Simple Simon® is “all-in-one”. Reagents, calibrated reader (measuring unit) and other are in the same product. Reagents and other things have the same lot number and the same expiration date as the reader. Along with each reagent lot comes a factory-controlled, calibrated, “ready-to-use” reader.
För mer information kontakta fredrik.wells@zafena.se
Worldwide delivery
Tekniska data: Simple Simon® PT
Produkt: ZAF-101
Mätområde: 0.7- 10 INR
Mättid: ca 1min vid INR 2.5
Prov: 10µL blod eller plasma
Tar liten plats: 15*10cm
Detektor: dubbla optiska ljusgångar
Störs av lupus-antikroppar: Nej, som annan Owren
EVF kompensation: Ja
Uppvärmingstid: Ingen
Strömtillförsel: Batteri/USB
LIS/HIS uppkopplingsbar: Ja, via Zafena Simple Simon Plus skärm ZAF-552
Produktdokument
Information om USB & batterivarnarfunktionen på Simple Simon® PT.
Säkerhetsdatablad N273M N223N Simple Simon® PT
Oberoende utvärderingar
SKUP/2011/84* Simple Simon PT och MixxoCap : Sammanfattning
SKUP/2011/84* Simple Simon PT och MixxoCap : Fullständig rapport
SKUP/2007/57* Simple Simon PT : Sammanfattning
SKUP/2007/57* Simple Simon PT : Fullständig rapport
Tidningsartiklar och publikationer
NyTeknik, 2005: Blodets tjocklek kan mätas på minuten
Clinical Chemistry clinchem.2010.146233 : Discrepancies in International Normalized Ratio Results between Instruments
Klinisk Biokemi i Norden Nr 4, vol. 29, 2017 : Nya orala antikoagulantia – interferenser kan orsaka felaktiga resultat i koagulationsutredningar NOAC
You may also like…
-
Reagent and Buffer – for determination of PT INR with Simple Simon® PT
Read more -
MixxoCap® [ZAF-101-3] patented sample-capillary with mixing function 10uL
Read more -
POC-Workstation – General access point for MedTech – Workflow optimazation and automation
Read more -
ZAP – Zafena Abnormal Plasma – Quality control for PT INR
Read more